Special Features:
Interchangeable drums
Thanks to the simple drum‑change system, the GMPC II can handle batch sizes from 0.9 L to 56 L.
Compact design and functional layout
All necessary system components, especially the inlet and exhaust air units, are integrated into a single machine housing. This ensures easy installation as a pilot-scale unit.
Technical Data
| Drum diameter | 440 / 16“ | 540 / 20" | 640 / 24" | 750 / 30" |
|---|---|---|---|---|
| Volume in liters | 2.0 | 9.0 | 24.0 | 56.0 |
| Max. charging weight (0.8 kg / l) in kg | 1.6 | 7.0 | 19.0 | 45.0 |
Tablet Coating Process
The drum coating process is suitable for coating and refining tablets, minitablets and capsules.
During the drum coating process, the tablets, capsules or minitablets are moved gently and in a controlled manner in a drum where the coating is applied. The key is to distribute the coating material as evenly as possible. This is ensured by the appropriate spray equipment and homogeneous mixing.